Incinerating Capability of ACE THERMAL WASTE DECOMPOSER Type 0.5
<<BACK

No

Incinerating material

Applicable Industry

Processing Capability
Per Hour

1

Medical waste

Hospitals

50KG

2

Medical diaper

Hospitals, Nursery homes

50KG

3

Residue of processed marine products

Fishery, Wholesale markets

60KG

4

Residue of processed agricultural products

Agriculture, Wholesale markets

60KG

5

Surplus foods

Hotels, Hospitals

55KG

6

Mowed turf from golf courses, etc.

Parks, Golf courses

50KG

7

Timbers

Construction, Woodwork

50KG

8

Surplus timbers from construction site

Woodwork plants

60KG

9

Dust, carbon substances

Boiler, Chimney

50KG

10

Sludge form paints, etc.

Paint industry

25KG

11

Soiled mud from elutriation tanks

Chemical factories, Food factories

Remark 1

12

Incineration cinder

Ordinary incinerator

Remark 2

13

Seashells, Animals

Meat products processing factories,
Marine products processing factories

50KG

Remark 1) Incinerating capability varies depending on the water containment of the soiled mud.(Even the water containment is 90%, possible to incinerate)
Remark 2) This is the case that ACE THERMAL WASTE DECOMPOSER re-incinerates the cinder incinerated once in the temperature under 700 centigrade.

Exposition Outline of the structure and Capability

Item

Type/contents

capabiliy

1

Model

ACE Type 0.5


2

Structure

Furnace Floor Measure: Approximately 600mm x 820mm

Approximately 0.49M2

Furnace Cubic Contents: Primary combustion Room

Approximately 0.49M3

Furnace Internal Surface: CASTABLE Refractory Material

Approximately 150`200mmt

Dust Collection Machine: CYCLONE Method

1 unit

Chimney Stack: Stainless Made

0.6mH

Weight

Approximately 4.3t

3

Combustion Method

High Temperature combustion Method

1,000`2,000 Centigrade

Combustion Improver

Waste oil

4

Incineration capability

Refer to the attached table

Less than 50KG

5

Cooling Method

Air-cooling


6

Operation Method

Manual


7

Accessories

Combustion Fan (with Timer)

1.5KW

Supplemental Fuel Pump

0.35KW

Thermometer

0`1,500 Centigrade

8

Endurance

Almost Maintenance-free

Using refractory material for high pressure gas (chlorine group) combustion parts

9

Economization

Using Waste oil for supplemental fuel.

Reducing operational cost

No Burner, no Lattice

Very few possibility of breakdown

10

Ecology Measure

No Flue Gas

Demonstration test available

Operating in the temperature degrading Dioxin type substances

1,000`3,000 centigrade

Producing very few surplus dust

Close to melting temperature point

11

Operational Convenience

This is small type incinerator which is not applicable to the regulations.
You can set up without any legal procedure.